摘要
数据中心机房作为现代信息技术的核心设施之一,能耗问题已经成为其发展的重大挑战。弱电系统作为机房的重要组成部分,影响着机房的能源消耗和运维成本。绿色节能设计在弱电系统中的应用显得尤为重要。本文深入分析了数据中心机房弱电系统的节能设计方法,提出了一些有效的设计理念和技术措施,如优化设备布局、采用节能设备、智能化控制等,旨在降低能耗并提升系统运行的可持续性。文章通过具体案例分析,展示了这些绿色节能设计在实际应用中的成效,并指出了目前存在的挑战和未来的改进方向。
关键词: 数据中心机房;弱电系统;绿色节能;设计优化;可持续性
Abstract
As one of the core facilities of modern information technology, data center rooms are facing significant challenges in energy consumption during their development. The weak current system, as an important component of the room, affects its energy consumption and operation and maintenance costs. Therefore, the application of green and energy-saving design in weak current systems is particularly crucial. This paper deeply analyzes the energy-saving design methods for weak current systems in data center rooms and proposes several effective design concepts and technical measures, such as optimizing equipment layout, adopting energy-saving equipment, and implementing intelligent control. These measures aim to reduce energy consumption and enhance the sustainability of system operation. Through specific case studies, the paper demonstrates the effectiveness of these green and energy-saving designs in practical applications, and points out the current challenges and future improvement directions.
Key words: Data center room; Weak current system; Green and energy-saving; Design optimization; Sustainability
参考文献 References
[1] 符军.数据中心机房温湿度预测方法研究[J].电脑知识与技术,2025,21(12):22-24.
[2] 陈红兵,卢浩阳,王聪聪,等.数据中心机房气流组织优化途径及效果分析[J].煤气与热力,2025,45(04):30-35.
[3]郑荣锋,周超,卢云,等.数据中心机房智能巡检系统设计及应用[J].无线互联科技,2025,22(05):28-31.
[4] 余丹,林捷.国家地震台网数据中心机房智能监控系统设计与实现[J].地震地磁观测与研究,2025,46(01):162-170.
[5] 周子航,周明升.基于物联网的数据中心机房3D数字孪生管理平台[J].现代信息科技,2024,8(24):171-174+181.
[6] 陈方正,穆春宇,石咸胜.数据中心机房UPS供电系统可靠度模糊评价研究[J].微型电脑应用,2024,40(12):207-210.
[7] 王沁,顾明,王洁丽,等.一种数据中心机房多维效能智慧评估方案浅析[J].电信工程技术与标准化,2024,37(S2): 93-100.
[8] 王志弘.企业“绿色”数据中心机房的建设[J].中国战略新兴产业,2024,(35):127-129.